CPI 400W Ku-band Outdoor TWT Amplifier (NEW O.E.M)

In stock

Details

Manufacturer:

CPI

Model:

T04UO Series

Condition:

New from original equipment manufacturer

Quantity:

10

Warranty:

as implied by manufacturer

Description:

CPI 400W Outdoor TWT Amplifier — high efficiency in an environmentally sealed compact package designed for outdoor operation

Request a quote

Description

CPI 400W Ku-band Outdoor TWT Amplifier (NEW O.E.M)

Manufacturer: CPI
Model: T04UO Series
Condition: New from original equipment manufacturer
Quantity: 10
Warranty: as implied by manufacturer
Description: CPI 400W Outdoor TWT Amplifier — high efficiency in an environmentally sealed compact package designed for outdoor operation

Additional Options:

  • 1 RU Remote Control Panel
  • Extended Frequency (12.75-14.5 GHz)
  • Redundant and Power Combined Subsystems
  • Additional External Receive Band Reject Filter (increases loss by a minimum 70 dB up to 12.7 GHz)
  • SSIPA with Variable Attenuator (provides RF Level Adjust Range of 0 to 30 dB)
  • Integral Linearizer (requires SSIPA with attenuator option)
  • Integrated 1:1 switch control and drive
  • Ethernet Interface
  • Higher Operating Temperature Limit (+60°C)
  • L-Band Block Up-converter (BUC - requires SSIPA option)

*For data sheet please see documentation TAB above.

Key specifications
Type: outdoor Ku-band TWT amplifier, CPI T04UO
Frequency: 13.75 to 14.50 GHz (12.75 to 14.50 GHz with extended frequency option)
Output power: 400 W minimum at the TWT (56.0 dBm), 350 W minimum at the flange
Gain: 46 dB minimum at rated power, 52 dB small signal (70 and 75 dB with SSIPA option)
Intermodulation: -24 dBc maximum with two equal carriers 7 dB below rated power (4 dB with linearizer)
Harmonic output: -60 dBc at rated power
Phase noise: 12 dB below the IESS-308 mask
Connections: RF input type N female, RF output WR-75 waveguide, RF monitor type N
Monitor and control: RS-422/485 serial interface, Ethernet as option
Size and weight: 260 x 267 x 521 mm, 25 kg
Power: 90 to 264 VAC, 1.35 kW typical, power factor 0.95 minimum
Operating temperature: -40 to +55 degrees C, including solar loading

For more information, please contact us at sales@ai-sat.com